Heat Pump Size Calculator

Estimate the heat pump size a home needs in BTU and tons from its floor area, climate zone and insulation, before a full Manual J load calculation. It gives the load in BTU per hour and tons, the nominal size, and in cold zones the heating rating a cold-climate model needs.

Your numbers

sq ft

Every floor the heat pump heats and cools, finished basement included.

Not sure? The DOE and PNNL county guide in the sources lists every county's zone.

ft
BTU/h

From a Manual J or the heat loss calculator. Used for the cold-climate check in any zone.

Nominal heat pump size

–

Load estimate
–
Range for zone 4 (moderate)
–
BTU per square foot used
–

The calculation runs in your browser and ParrotNotes does not store your numbers. They sit in the page address so you can bookmark or share the result.

How the heat pump size estimate works

Multiply the conditioned floor area by the BTU per square foot for the climate, choosing the low end of the range for a tight, well insulated house, the middle for an average one and the high end for a leaky or older one. Scale it by the ceiling height. Divide by 12,000 for tons, then take the smallest nominal size, in half-ton steps from 1.5 to 5 tons, that covers it.

Worked example: 1,800 sq ft in zone 4 (moderate), average insulation, 8 ft ceilings. The range is 20 to 25 BTU per square foot, so the middle is 22.5: 1,800 × 22.5 = 40,500 BTU per hour, 3.38 tons. The nominal size that covers it is 3.5 tons.

In a cold zone (5 to 7) the calculator adds a heating check. A cold-climate heat pump at the ENERGY STAR minimum keeps 70% of its 47°F capacity at 5°F, so to deliver 54,000 BTU per hour at 5°F it needs a 47°F heating rating of at least 54,000 ÷ 0.70 = 77,143 BTU per hour. If you have a design heating load from a Manual J or the heat loss calculator, type it in and the check uses it in any zone.

BTU per square foot by climate zone

Carrier's figures by climate, matched to the IECC climate zones by this calculator. Carrier gives about 20 BTU per square foot as standard in a moderate climate; the calculator takes 20 to 25 there, the lower half of Carrier's general 20 to 30 range. The example places come from the DOE Building America county guide.

BTU per square foot and square feet per ton for each IECC climate zone
ZoneExample placesClimateBTU per sq ftSq ft per ton
1Miamihot25 to 30400 to 480
2Houston, Phoenixhot25 to 30400 to 480
3Dallas, Atlanta, Las Vegashot25 to 30400 to 480
4Washington DC, New York City, St. Louis, Seattlemoderate20 to 25480 to 600
5Chicago, Boston, Denvercold30 to 35343 to 400
6Minneapolis, Burlington VTcold30 to 35343 to 400
7Fargo, Duluth, northern Mainecold30 to 35343 to 400

Heat pump size chart by square footage

Carrier's chart, a general estimate it says is no substitute for a Manual J load calculation. A ton is about 12,000 BTU per hour of heating or cooling, and most homes use 1.5 to 5 tons.

Carrier's home size to heat pump BTU and tons chart
Home size, sq ftBTU per hourTons
600 to 1,00018,000 to 24,0001.5 to 2
1,000 to 1,50024,000 to 36,0002 to 3
1,500 to 2,00036,000 to 48,0003 to 4
2,000 to 2,50048,000 to 60,0004 to 5
2,500 to 3,00060,000 to 72,0005

One unit, two loads

A furnace only heats and an air conditioner only cools, but a heat pump does both, so its size has to fit two loads. In a hot climate the cooling load usually sets the size. In a cold one the heating load is often far bigger than the cooling load, and a unit big enough for January can be too big for July, short cycling and leaving the air damp. Variable-speed and staged units turn down to soften that.

That is why this page shows the size range for the zone and, where it matters, the heating rating to look for. If those two point to very different sizes, that is the question for the load calculation.

Cold climates: read the capacity at 5°F

A heat pump moves heat from the outdoor air, and there is less of it to move on a cold night, so its heating output falls as the temperature drops. ENERGY STAR's cold climate criteria set a floor: at 5°F the unit keeps at least 70% of its 47°F heating capacity, with a COP of at least 1.75. The model's spec sheet shows what it actually delivers at 5°F and at other temperatures.

The Building America guide from the Department of Energy and PNNL sets out approaches running from sizing for cooling, with the warmest balance point (the coldest outdoor temperature at which the unit carries the whole house) and the most backup heat, to sizing for the design heating load at the location's design temperature, with the coldest balance point. Backup electric resistance heat makes up any shortfall at much lower efficiency, so the guide says to keep it to a minimum. It also warns not to select equipment on nameplate capacity.

Where Manual J comes in

BTU per square foot cannot see the windows, the duct runs, the attic or the local design temperatures. ANSI/ACCA Manual J can: it works the heating and cooling loads room by room, and Manual S then selects equipment whose capacity at the design conditions fits them. This page is an estimate, not a substitute for that calculation. Use it to get a first number, to check a quote that looks far off, and to know what to ask the contractor.

For HVAC and home services reps: what to write down

The size comes from the load calculation. The sale comes from what the homeowner tells you: which rooms are cold or hot, what the bills look like in winter and summer, what heats the house now, whether they want to keep the furnace as backup, and who else decides. Write it down while you are in the house, and read it back before you send the quote.

Sources, read on 2026-10-29:

Keeping the furnace, or replacing it? The furnace size calculator sizes the gas side. For a design heating load from the walls, windows and air leaks, use the heat loss calculator; for a single room or a room air conditioner, the BTU calculator.